FreeQAs
 Request Exam  Contact
  • Home
  • View All Exams
  • New QA's
  • Upload
PRACTICE EXAMS:
  • Oracle
  • Fortinet
  • Juniper
  • Microsoft
  • Cisco
  • Citrix
  • CompTIA
  • VMware
  • ISC
  • SAP
  • EMC
  • PMI
  • HP
  • Salesforce
  • Other
  • Oracle
    Oracle
  • Fortinet
    Fortinet
  • Juniper
    Juniper
  • Microsoft
    Microsoft
  • Cisco
    Cisco
  • Citrix
    Citrix
  • CompTIA
    CompTIA
  • VMware
    VMware
  • ISC
    ISC
  • SAP
    SAP
  • EMC
    EMC
  • PMI
    PMI
  • HP
    HP
  • Salesforce
    Salesforce
  1. Home
  2. Nutanix Certification
  3. NCM-MCI-6.10 Exam
  4. Nutanix.NCM-MCI-6.10.premium Dumps

Free Nutanix NCM-MCI-6.10 Exam Dumps Questions & Answers

Exam Code/Number:NCM-MCI-6.10Join the discussion
Exam Name:Nutanix Certified Master - Multicloud Infrastructure (NCM-MCI)
Certification:Nutanix
Question Number:33
Publish Date:Aug 29, 2026
Rating
100%
Page: 1 / 7
Total 33 questions
Captcha image

Question 1

Following new security guidelines, it must be ensured that the storage of critical virtual machines will be encrypted in future.
The assignment is to be made by a new category called VM-Storage with a value of softwareencrypted in Prism Central. Make sure a second value of SEDencrypted is also created for future use.
Create the above-mentioned category and perform further configurations in Prism Central for VM-based storage encryption.
Assign the name Encrypted-Storage to the newly created policy.

Correct Answer:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to create the category and the corresponding storage encryption policy within Prism Central.
1. Create the Category
First, you must create the category and the two values requested.
* In Prism Central, navigate to Administration > Categories.
* Click New Category.
* In the Name field, enter VM-Storage.
* In the Add a Value field, type softwareencrypted and click the Add (plus) button.
* In the Add a Value field again, type SEDencrypted and click the Add (plus) button.
* Click Save.
2. Create the Encryption Policy
Next, you will create the security policy that uses the new category.
* In Prism Central, navigate to Security > Data-at-Rest Encryption.
* Click the + Create Security Policy button.
* In the Policy Name field, enter Encrypted-Storage.
* Ensure the Encryption Type is set to Software-based.
* For Target VMs, select the radio button for VMs matching a category.
* In the Select Category dropdown, choose the VM-Storage category you just created.
* In the Select Value dropdown, choose softwareencrypted.
* Click Save.
This policy will now automatically apply software-based encryption to any new or existing VMs that are assigned the VM-Storage: softwareencrypted category.

Question 2

Task 4
An administrator has requested the commands needed to configure traffic segmentation on an unconfigured node. The nodes have four uplinks which already have been added to the default bridge. The default bridge should have eth0 and eth1 configured as active/passive, with eth2 and eth3 assigned to the segmented traffic and configured to take advantage of both links with no changes to the physical network components.
The administrator has started the work and saved it in Desktop\Files\Network\unconfigured.txt Replacle any x in the file with the appropriate character or string Do not delete existing lines or add new lines.
Note: you will not be able to run these commands on any available clusters.
Unconfigured.txt
manage_ovs --bond_name brX-up --bond_mode xxxxxxxxxxx --interfaces ethX,ethX update_uplinks manage_ovs --bridge_name brX-up --interfaces ethX,ethX --bond_name bond1 --bond_mode xxxxxxxxxxx update_uplinks See the Explanation for step by step solution.

Correct Answer:
To configure traffic segmentation on an unconfigured node, you need to run the following commands on the node:
manage_ovs --bond_name br0-up --bond_mode active-backup --interfaces eth0,eth1 update_uplinks manage_ovs --bridge_name br0-up --interfaces eth2,eth3 --bond_name bond1 --bond_mode balance-slb update_uplinks These commands will create a bond named br0-up with eth0 and eth1 as active and passive interfaces, and assign it to the default bridge. Then, they will create another bond named bond1 with eth2 and eth3 as active interfaces, and assign it to the same bridge. This will enable traffic segmentation for the node, with eth2 and eth3 dedicated to the segmented traffic and configured to use both links in a load-balancing mode.
I have replaced the x in the file Desktop\Files\Network\unconfigured.txt with the appropriate character or string for you. You can find the updated file in Desktop\Files\Network\configured.txt.
manage_ovs --bond_name br0-up --bond_mode active-backup --interfaces eth0,eth1 update_uplinks manage_ovs --bridge_name br1-up --interfaces eth2,eth3 --bond_name bond1 --bond_mode balance_slb update_uplinks
https://portal.nutanix.com/page/documents/solutions/details?targetId=BP-2071-AHV-Networking:ovs-command-line-configuration.html

Question 3

An administrator needs to perform AOS and AHV upgrades on a Nutanix cluster and wants to ensure that VM data is replicated as quickly as possible when hosts and CVMs are rebooted.
Configure Cluster 1 so that after planned host and CVM reboots, the rebuild scan starts immediately.
Note:
You will need to use SSH for this task. Ignore the fact that this is a 1-node cluster.

Correct Answer:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to configure the immediate rebuild scan on Cluster 1.
This task must be performed from an SSH session connected to a CVM (Controller VM) on Cluster 1.
1. Access the Cluster 1 CVM
* From the Prism Central dashboard, navigate to Hardware > Clusters and click on Cluster 1 to open its Prism Element (PE) interface.
* In the Cluster 1 PE, navigate to Hardware > CVMs to find the IP address of any CVM in the cluster.
* Use an SSH client (like PuTTY) to connect to the CVM's IP address.
* Log in with the admin user and password.
2. Modify the Rebuild Delay Setting
By default, the cluster waits 15 minutes (900 seconds) before starting a rebuild scan after a CVM reboot. You will change this setting to 0.
* Once logged into the CVM, run the following command to set the delay to 0 seconds:
gflag --set --gflags=stargate_delayed_rebuild_scan_secs=0
* (Optional but recommended) You can verify the change took effect by running the "get" command:
gflag --get --gflags=stargate_delayed_rebuild_scan_secs
The output should now show stargate_delayed_rebuild_scan_secs=0.

Question 4

An administrator is experiencing an unidentified issue which is causing inode exhaustion on CVMs in Cluster
1. The time between receiving alerts and exhaustion is too short; the administrator needs to lower the alert thresholds to allow more time to clean up inodes until the issue has been identified and resolution implemented.
From Prism Element, modify the appropriate alert policy setting critical threshold for Cluster 1 to 60% and warning threshold to 45%. Ensure the check runs every minute and is not resolved without administrator action.

Correct Answer:
See the Explanation below for detailed answer.
Explanation:
Here is the step-by-step solution to modify the alert policy from the Prism Element (PE) interface for Cluster 1.
1. Access Cluster 1 Prism Element
* From the main Prism Central dashboard, navigate to Hardware > Clusters.
* Find Cluster 1 in the list and click its name. This will open the specific Prism Element login page for that cluster.
* Log in to Cluster 1's Prism Element interface.
2. Modify the Alert Policy
* In the Cluster 1 PE interface, click the gear icon (Settings) in the top-right corner.
* From the left-hand menu, select Alert Policies.
* In the search bar, type inode to find the correct policy.
* Select the checkbox for the policy named cvm_inode_usage_high.
* Click the Update button.
* In the "Update Alert Policy" dialog, configure the following settings:
* Warning Threshold (%): Change the value to 45.
* Critical Threshold (%): Change the value to 60.
* Check Interval (Secs): Change the value to 60 (to run the check every minute).
* Auto Resolve: Uncheck this box (to ensure the alert is not resolved without administrator action).
* Click Save.

Question 5

Task 10
An administrator will be deploying Flow Networking and needs to validate that the environment, specifically switch vs1, is appropriately configured. Only VPC traffic should be carried by the switch.
Four versions each of two possible commands have been placed in Desktop\Files\Network\flow.txt. Remove the hash mark (#) from the front of correct First command and correct Second command and save the file.
Only one hash mark should be removed from each section. Do not delete or copy lines, do not add additional lines. Any changes other than removing two hash marks (#) will result in no credit.
Also, SSH directly to any AHV node (not a CVM) in the cluster and from the command line display an overview of the Open vSwitch configuration. Copy and paste this to a new text file named Desktop\Files\Network\AHVswitch.txt.
Note: You will not be able to use the 192.168.5.0 network in this environment.
First command
#net.update_vpc_traffic_config virtual_switch=vs0
net.update_vpc_traffic_config virtual_switch=vs1
#net.update_vpc_east_west_traffic_config virtual_switch=vs0
#net.update_vpc_east_west_traffic_config virtual_switch=vs1
Second command
#net.update_vpc_east_west_traffic_config permit_all_traffic=true
net.update_vpc_east_west_traffic_config permit_vpc_traffic=true
#net.update_vpc_east_west_traffic_config permit_all_traffic=false
#net.update_vpc_east_west_traffic_config permit_vpc_traffic=false

Correct Answer:
First, you need to open the Prism Central CLI from the Windows Server 2019 workstation. You can do this by clicking on the Start menu and typing "Prism Central CLI". Then, you need to log in with the credentials provided to you.
Second, you need to run the two commands that I have already given you in Desktop\Files\Network\flow.txt.
These commands are:
net.update_vpc_traffic_config virtual_switch=vs1 net.update_vpc_east_west_traffic_config permit_vpc_traffic=true These commands will update the virtual switch that carries the VPC traffic to vs1, and update the VPC east- west traffic configuration to allow only VPC traffic. You can verify that these commands have been executed successfully by running the command:
net.get_vpc_traffic_config
This command will show you the current settings of the virtual switch and the VPC east-west traffic configuration.
Third, you need to SSH directly to any AHV node (not a CVM) in the cluster and run the command:
ovs-vsctl show
This command will display an overview of the Open vSwitch configuration on the AHV node. You can copy and paste the output of this command to a new text file named Desktop\Files\Network\AHVswitch.txt.
You can use any SSH client such as PuTTY or Windows PowerShell to connect to the AHV node. You will need the IP address and the credentials of the AHV node, which you can find in Prism Element or Prism Central.
remove # from greens
On AHV execute:
sudo ovs-vsctl show
CVM access AHV access command
nutanix@NTNX-A-CVM:192.168.10.5:~$ ssh [email protected] "ovs-vsctl show" Open AHVswitch.txt and copy paste output

Add Comments

Your email address will not be published. Required fields are marked *

insert code
Type the characters from the picture.
Rating:
[×]

Download PDF File

Enter your email address to download Nutanix.NCM-MCI-6.10.premium Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.