FreeQAs
 Request Exam  Contact
  • Home
  • View All Exams
  • New QA's
  • Upload
PRACTICE EXAMS:
  • Oracle
  • Fortinet
  • Juniper
  • Microsoft
  • Cisco
  • Citrix
  • CompTIA
  • VMware
  • ISC
  • SAP
  • EMC
  • PMI
  • HP
  • Salesforce
  • Other
  • Oracle
    Oracle
  • Fortinet
    Fortinet
  • Juniper
    Juniper
  • Microsoft
    Microsoft
  • Cisco
    Cisco
  • Citrix
    Citrix
  • CompTIA
    CompTIA
  • VMware
    VMware
  • ISC
    ISC
  • SAP
    SAP
  • EMC
    EMC
  • PMI
    PMI
  • HP
    HP
  • Salesforce
    Salesforce
  1. Home
  2. Cisco Certification
  3. 350-601 Exam
  4. Cisco.350-601.v2022-12-08.q308 Dumps
  • ««
  • «
  • …
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • …
  • »
  • »»
Download Now

Question 226

A storage engineer must configure zoning on a Cisco MDS 9000 Series switch. Drag and drop actions from the left into the order on right

Correct Answer:

Explanation
Graphical user interface, table Description automatically generated with medium confidence


https://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/6_2/ configuration/guides/fabric/nx-os/nx_os_fabric/zone.html
insert code

Question 227

A company is investigating different options for IT automation tools. The IT team has experience with python programming language and scripting using a declarative language. The proposed tool should be easy to set up and should not require installing an agent on target devices. The team will also need to build custom modules based on the python programming language to extend the tools functionality. Which automation tool should be used to meet these requirements?

Correct Answer: B
insert code

Question 228

An engineer must shut down the Ethernet 1/2 interface when the Ethernet 4/5 interface state is down. Drag and drop the CLI commands from the bottom onto the blanks in the exhibit to implement this EEM. Not all commands are used.

Correct Answer:
Explanation
Text Description automatically generated
insert code

Question 229

A cisco Nexus 9000 series switch experiences a startup configuration comuption. The engineer must implement a procedure to recover configuration file from the switch. Which command set must be used?

Correct Answer: C
Explanation
Problems, such as memory corruption, can occur that make it necessary for you to recover your configuration from a backed-up version.
Each time that you enter a copy running-config startup-config command, a binary file is created and the ASCII file is updated. A valid binary configuration file reduces the overall boot time significantly. A binary file cannot be uploaded, but its contents can be used to overwrite the existing startup configuration. The write erase command clears the binary file.
SUMMARY STEPS
1. write erase
2. reload
3. copy configuration-file running-configuration
4. copy running-config startup-config
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/fundamentals/configuration/guide
insert code

Question 230

Refer to the exhibit.

Which command is run from the Guest Shell to set the description on the first five interfaces of the Cisco Nexus switch?

Correct Answer: D
insert code
  • ««
  • «
  • …
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download Cisco.350-601.v2022-12-08.q308 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.