FreeQAs
 Request Exam  Contact
  • Home
  • View All Exams
  • New QA's
  • Upload
PRACTICE EXAMS:
  • Oracle
  • Fortinet
  • Juniper
  • Microsoft
  • Cisco
  • Citrix
  • CompTIA
  • VMware
  • ISC
  • SAP
  • EMC
  • PMI
  • HP
  • Salesforce
  • Other
  • Oracle
    Oracle
  • Fortinet
    Fortinet
  • Juniper
    Juniper
  • Microsoft
    Microsoft
  • Cisco
    Cisco
  • Citrix
    Citrix
  • CompTIA
    CompTIA
  • VMware
    VMware
  • ISC
    ISC
  • SAP
    SAP
  • EMC
    EMC
  • PMI
    PMI
  • HP
    HP
  • Salesforce
    Salesforce
  1. Home
  2. USGBC Certification
  3. LEED-AP-BD-C Exam
  4. USGBC.LEED-AP-BD-C.v2026-04-11.q171 Dumps
  • ««
  • «
  • …
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • …
  • »
  • »»
Download Now

Question 46

When attempting Regional Priority Credit, what must be provided in LEED Online?

Correct Answer: A
To pursue a Regional Priority Credit in LEED, project teams must provide the latitude and longitude (A) of the project in LEED Online. This information helps the LEED system identify which regional priorities are applicable based on the project's geographic location. Regional Priority Credits are customized credits specific to environmental concerns in a particular area, rewarding projects for addressing local issues. Other options like heating and cooling degree days (B), climate zone (C), and ENERGY STAR score (D) are not required to qualify for these credits.
insert code

Question 47

A project's massing and site orientation can have a direct impact on which of the following prerequisites?

Correct Answer: A
Minimum Energy Performance
A project's massing and site orientation can have a direct impact on the minimum energy performance prerequisite, which requires projects to demonstrate a percentage of energy cost savings compared to a baseline building. Massing and orientation affect the amount of solar heat gain, daylight availability, natural ventilation potential, and wind exposure of the building, which in turn influence the heating, cooling, lighting, and ventilation loads and strategies. By optimizing the massing and orientation of the building, projects can reduce their energy consumption and improve their thermal and visual comfort.
References:
* Reference Guide for Building Design and Construction v4 - Pages 279-2801
* Building Massing & Orientation | Sustainability Workshop2
insert code

Question 48

Which of the following statements are true for Erosion and Sedimentation Control (ESC) plan prerequisite compliance?

Correct Answer: B
For the Sustainable Sites (SS) Prerequisite: Construction Activity Pollution Prevention, a compliant Erosion and Sedimentation Control (ESC) plan can be developed or modified during the design phase of LEED certification (B). This flexibility allows the project team to adjust the plan as needed to ensure proper site protection measures before and during construction. An ESC plan is essential to prevent soil erosion, waterway sedimentation, and airborne dust, aligning with LEED's environmental protection standards.
insert code

Question 49

What building classification requires the energy model to determine the predicted power usage effectiveness (PUE) for Energy and Atmosphere Prerequisite, Minimum Energy Performance?

Correct Answer: D
This building classification requires the energy model to determine the predicted power usage effectiveness (PUE) for Energy and Atmosphere Prerequisite, Minimum Energy Performance, because data centers have high energy intensity and cooling demand, and PUE is a metric that measures how efficiently a data center uses energy12.
insert code

Question 50

Massing and orientation in Integrative Process Credit. Integrative Process evaluates how rotating the building
90 degrees affects

Correct Answer: A
Explanation
Massing and orientation are important factors that affect the energy performance of a building. Massing refers to the shape and size of the building, and orientation refers to the direction that the building faces. By rotating the building 90 degrees, the project team can evaluate how the change in orientation affects the energy loads of the building, such as heating, cooling, and lighting. For example, a building that faces south may receive more solar heat gain and daylight than a building that faces north, which may reduce the need for artificial lighting and heating, but increase the need for cooling and shading. The project team can use the results of the analysis to optimize the massing and orientation of the building to achieve the best energy performance.
References:
* LEED v4 Reference Guide for Building Design and Construction, Integrative Process Credit: Integrative Process, page 811
* Integrative Process Worksheet2
insert code
  • ««
  • «
  • …
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-BD-C.v2026-04-11.q171 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.