Question 111

What supporting material is required for all LEED Building Design and Construction projects in order to document Location and Transportation Credit, Bicycle Facilities for the bicycle network?

Correct Answer: C
The Location and Transportation Credit, Bicycle Facilities, requires the project team to provide a vicinity map that shows the bicycle network, the route and the distance along the network to eligible destination(s) for all LEED Building Design and Construction projects. The vicinity map is a supporting material that demonstrates that the project site is within a 200-yard (180-meter) walking distance of a bicycle network that connects to at least one of the following: diverse uses, public transportation, recreation facilities, or schools1. The vicinity map must also show the scale and the north arrow, and indicate the project site and the eligible destination(s)
2. The photographs of bicycle network signage and directional signposts, the photographs of the installed bicycle storage and shower facilities, and the manufacturer specifications for the chosen bicycle storage facilities are not required for the bicycle network, but for the bicycle storage and shower facilities.
References:
*LEED v4 Reference Guide for Building Design and Construction, Location and Transportation Credit:
Bicycle Facilities, page 1281
*LEED v4.1 Bicycle Storage Requirements
insert code

Question 112

Increasing which of the following variables will require an increase in the outdoor airflow rate under Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance?

Correct Answer: B
Explanation
The outdoor airflow rate is the amount of outdoor air that is supplied to the building by the ventilation system to dilute indoor air pollutants and provide fresh air for the occupants. The outdoor airflow rate depends on the ventilation standard that the project follows, which can be either ASHRAE 62.1-2010 or CEN Standard EN
15251-20071. Both standards specify the minimum outdoor airflow rate per person and per unit area for different occupancy types and zones. Therefore, increasing the number of occupants will require an increase in the outdoor airflow rate to maintain the minimum ventilation level. The other variables, such as supply air velocity, system ventilation efficiency, and supply air temperature set point, do not directly affect the outdoor airflow rate, although they may influence the energy consumption and thermal comfort of the ventilation system.
References:
* LEED Reference Guide for Building Design and Construction v4
* Minimum Indoor Air Quality Performance
* Ventilation for Acceptable Indoor Air Quality - ASHRAE
* Indoor environmental input parameters for design and assessment of ... - CEN
insert code

Question 113

Which of the following Building Product Disclosure and Optimization credits under the Materials and Resources category would a project team achieve by using insulation material that is cradle-to-cradle V3 Gold certified?

Correct Answer: B
Detailed Explanation:
Cradle-to-cradle certification (Gold level) meets the requirements for Material Ingredient Optimization under Option 2. It demonstrates the product's compliance with advanced environmental standards, supporting the LEED focus on transparency and optimization of building materials to minimize their environmental and human health impacts.
insert code

Question 114

Which of the following Water Efficiency credits differ between LEED Building Design and Construction:
New Construction and LEED Building Design and Construction: Healthcare?

Correct Answer: C
Explanation
LEED Building Design and Construction: Healthcare has additional appliance and process water requirements in Water Efficiency Prerequisite, Indoor Water Use Reduction LEED Building Design and Construction: New Construction and LEED Building Design and Construction:
Healthcare have the same Water Efficiency credits, except for the Cooling Tower Water Use credit, which is only applicable to the former. However, the Indoor Water Use Reduction prerequisite differs between the two rating systems, as the Healthcare version requires additional calculations for appliance and process water use, such as medical equipment, laundry, and kitchen equipment.
References:
* Reference Guide for Building Design and Construction v4 - Pages 256-3171
* LEED v4: Building Design + Construction Guide - U.S.Green Building Council2
insert code

Question 115

During construction, a value engineering exercise was conducted. This exercise has resulted in cost savings for the project. However, it is expected that the changes will affect some of the energy efficiency measures.
The team has already submitted Energy and Atmosphere Credit, Optimize Energy Performance for review, and Green Business Certification Inc. (GBCI) returned an anticipated reply. What should the project team do in this situation?

Correct Answer: C
When design changes occur during construction that impact energy efficiency measures, it is imperative to update the energy model to reflect these modifications. The LEED BD+C process requires that the energy model accurately represents the final design to ensure that the projected energy performance aligns with actual outcomes. Therefore, the project team must incorporate the changes into their energy model and assess the effect on the Optimize Energy Performance credit. This approach ensures that the project remains compliant with LEED requirements and that any potential impacts on energy performance are properly evaluated.
insert code
  • ««
  • «
  • …
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-BD-C.v2026-04-11.q171 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.