FreeQAs
 Request Exam  Contact
  • Home
  • View All Exams
  • New QA's
  • Upload
PRACTICE EXAMS:
  • Oracle
  • Fortinet
  • Juniper
  • Microsoft
  • Cisco
  • Citrix
  • CompTIA
  • VMware
  • ISC
  • SAP
  • EMC
  • PMI
  • HP
  • Salesforce
  • Other
  • Oracle
    Oracle
  • Fortinet
    Fortinet
  • Juniper
    Juniper
  • Microsoft
    Microsoft
  • Cisco
    Cisco
  • Citrix
    Citrix
  • CompTIA
    CompTIA
  • VMware
    VMware
  • ISC
    ISC
  • SAP
    SAP
  • EMC
    EMC
  • PMI
    PMI
  • HP
    HP
  • Salesforce
    Salesforce
  1. Home
  2. USGBC Certification
  3. LEED-AP-BD-C Exam
  4. USGBC.LEED-AP-BD-C.v2026-04-11.q171 Dumps
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • …
  • »
  • »»
Download Now

Question 16

An office building design has demonstrated reductions in landscape water use of 30% over baseline and indoor water use of 40%. These reductions qualify the project for:

Correct Answer: D
Detailed Explanation:
A reduction of 30% in outdoor water use qualifies the project for one point under the Outdoor Water Use Reduction credit, and a 40% reduction in indoor water use qualifies for four points under the Indoor Water Use Reduction credit. LEED awards points for water conservation strategies that significantly reduce the demand for potable water.
insert code

Question 17

Which of the following statements is correct when defining the project boundary?

Correct Answer: C
. The land associated with the project supports typical operations
According to the LEED v4 Reference Guide for Building Design and Construction, the LEED project boundary must include all contiguous land that is associated with the project and supports its typical operations. This includes land altered as a result of construction and features used primarily by the project's occupants, such as hardscape (parking and sidewalks), septic or stormwater treatment equipment, and landscaping1. Therefore, statement C is correct when defining the project boundary. Statement A is incorrect because the LEED project boundary must be contiguous. Statement B is incorrect because the LEED project boundary can include more than one building, as long as they are on the same site and share a common scope of work. Statement D is incorrect because there is no such requirement for the gross floor area of the LEED project to be a certain percentage of the gross land area within the LEED project boundary.
Reference:
Reference Guide for Building Design and Construction v4 - Page 282
NC-v4.1 MPR2: Must use reasonable LEED boundaries | LEEDuser1
insert code

Question 18

An HVAC system consists of an air handler supplying conditioned air (mixture of return air and outdoor air) to an office, corridor, conference room and lobby. For Indoor Environmental Quality Prerequisite, Minimum Indoor Air Quality Performance, the ventilation rate procedure calculations must be based upon what HVAC system configuration?

Correct Answer: B
A multiple-zone system is a system that has one or more air handlers supplying conditioned air to more than one zone. A zone is a space or group of spaces within a building with heating and cooling requirements that are sufficiently similar so that desired conditions (e.g., temperature) can be maintained throughout using a single controlling device. The ventilation rate procedure calculations must be based on the multiple-zone system configuration because the HVAC system in the question serves different zones with different ventilation requirements. References: LEED v4 Reference Guide for Building Design and Construction, p.
6881; ASHRAE Standard 62.1-2010, Section 6.2.52
insert code

Question 19

A project team wants to educate the facility manager on the installed building systems to improve Indoor Environmental Quality. They want the facility manager to maintain the systems so that they will continue to function as intended. Which of the following should be provided to the facility manager?

Correct Answer: B
A preventive maintenance plan is a document that outlines the procedures and schedules for maintaining the building systems and equipment. It helps to ensure that the systems and equipment are operating efficiently and effectively, and that they meet the design intent and performance goals. A preventive maintenance plan can also help to reduce the risk of failures, breakdowns, and repairs, and extend the service life of the systems and equipment. A preventive maintenance plan is especially important for improving the indoor environmental quality, as it can prevent issues such as poor ventilation, air leaks, moisture problems, mold growth, and indoor air pollution. Therefore, the project team should provide the facility manager with a preventive maintenance plan for the building, along with the necessary training and resources to implement it.
Reference:
* LEED v4 Reference Guide for Building Design and Construction, Indoor Environmental Quality Credit: Enhanced Indoor Air Quality Strategies, page 6951
* LEED v4 Reference Guide for Building Design and Construction, Indoor Environmental Quality Credit: Thermal Comfort, page 7041
* LEED v4 Reference Guide for Building Design and Construction, Indoor Environmental Quality Credit: Acoustic Performance, page 7101
* Preventive Maintenance Plan - The Ridiculously Simple Guide
insert code

Question 20

What standard should an engineer use when establishing minimum ventilation rates for a new mechanically ventilated space to earn Indoor Environmental Quality, Minimum Indoor Air Quality Performance?

Correct Answer: B
ASHRAE 62.1-2010 is the standard that an engineer should use when establishing minimum ventilation rates for a new mechanically ventilated space to earn Indoor Environmental Quality, Minimum Indoor Air Quality Performance. This is the standard referenced by the LEED v4 BD+C Reference Guide for this prerequisite. Local building code, International Mechanical Code 2012, and the ventilation code requiring the greatest volume of outside air are not acceptable alternatives for this prerequisite.
Reference: LEED v4 BD+C Reference Guide, Indoor Environmental Quality Category, EQp Minimum Indoor Air Quality Performance, page 674.
insert code
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-BD-C.v2026-04-11.q171 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.