Question 6

You are working on the design of a new facility. The electrical riser of the building with high current power is located close to the area where sensitive IT equipment in the computer room will be located.
What should you recommend to reduce the amount of EMF coming from the electrical riser?

Correct Answer: D
To reduce Electromagnetic Fields (EMF) emanating from the electrical riser near sensitive IT equipment, three-phase power cabling in a combined cable (such as XLPE) is effective. Combined cabling helps reduce EMF by keeping the conductors tightly packed, which minimizes magnetic fields generated by current flow.
Cables like XLPE (cross-linked polyethylene) also offer better insulation, which helps mitigate EMF interference with nearby IT equipment.
Detailed Explanation:
Using a combined three-phase cable reduces EMF because the magnetic fields generated by each phase tend to cancel each other out when in close proximity. This arrangement helps reduce the overall magnetic field strength. In addition, XLPE and similar materials provide good insulation, making them a preferred choice for reducing EMF emissions around sensitive equipment.
EPI Data Center Specialist References:
EPI data center best practices recommend mitigating EMF interference through combined cabling arrangements, especially near areas where sensitive IT equipment is located. Reducing EMF is crucial to maintaining equipment reliability and ensuring compliance with safety standards.
insert code

Question 7

A data center is in an area where utility power is highly available-only a few outages per year, typically <1 hour per event and <50 hours/year not available. What type of generators should be installed?

Correct Answer: D
With infrequent/short outages, Standby (Emergency Standby Power, ESP) generators are appropriate; N+1 mitigates failure-to-start risk and supports concurrently maintainable designs.
References: ISO 8528-1 (generator rating definitions: ESP/PRP/Continuous), ANSI/TIA-942-B §6.2 (electrical redundancy).
insert code

Question 8

Do you need to consider blast protection when designing a data center?

Correct Answer: B
Blast protection should be considered if the data center or its location is a potential target or is near high-risk areas. Blast protection measures can protect both personnel and infrastructure from potential explosion impacts, which could be essential in areas with heightened security risks.
Detailed Explanation:
In areas where there may be risks of terrorist attacks or explosions due to nearby high-risk facilities, implementing blast protection measures helps safeguard the data center's infrastructure. These measures can include reinforced walls, blast-resistant windows, and secure entryways designed to withstand explosive forces.
EPI Data Center Specialist References:
While not specifically mandated by ANSI/TIA-942, EPI training advises considering local risk factors, including proximity to potential targets, when evaluating the need for blast protection. This approach is aligned with risk assessment and mitigation practices to ensure facility security.
insert code

Question 9

Where should raised-floor installation start?

Correct Answer: C
Best practice is to begin raised-floor installation at the center of the room, working outward. This minimizes alignment errors and ensures the tile grid is centered, which is critical for aisle containment and rack alignment.
Starting at the perimeter (A, B, D) causes cutting of tiles along both sides, misalignment with rack rows, and possible airflow inefficiencies. By starting at the center, tiles can be cut symmetrically around the edges, providing better aesthetics, balanced airflow, and structural stability.
Industry guidelines such as CISCA recommend this approach for raised floors in mission-critical spaces.
References: CISCA Raised Access Floor Guidelines, ANSI/TIA-942-B §6.3.
insert code

Question 10

The logical overview of the data center looks as pictured. To what TIA-942 Rating is this design made based on electrical only?

Correct Answer: A
The electrical design shown in the diagrams represents a TIA-942 Rating-4 configuration. This design includes full redundancy and fault tolerance, as demonstrated by the dual power distribution paths from the utility supply to the critical loads. Each power distribution path is equipped with its own UPS, ensuring that the ICT equipment and mechanical equipment have uninterrupted power in case of any single point of failure.
Detailed Explanation:
A Rating-4 data center requires two independent power paths that are fully redundant and capable of supporting the load independently. In the diagrams:
There are dual feeds from the utility supply, each going through separate transfer switches and power distribution paths.
Both paths have backup sources (+1) and serve critical components through separate UPS systems, providing a completely redundant setup.
The design also includes redundant paths to the mechanical equipment and ICT equipment, which further indicates the fault-tolerant characteristics of a Rating-4 infrastructure.
This setup allows for concurrent maintainability and ensures that no single failure in power distribution or UPS can impact the data center's operation, which is characteristic of the highest Tier/Rated-4 classification.
EPI Data Center Specialist References:
EPI guidelines confirm that TIA-942 Rating-4 requires full redundancy and fault tolerance for electrical infrastructure, ensuring continuous operation even during maintenance or failure events. This design meets all those requirements, thus aligning with Rating-4 standards.
insert code
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download EXIN.CDCS.v2026-03-09.q52 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.