Question 1

You have a NetApp ONTAP cluster consisting of four NetApp FAS8200 controllers with two NetApp CN1610 cluster switches running ONIAP 9.8 software. You are receiving several alert messages stating that the cluster network has degraded. After troubleshooting, you determine that the errors are being generated from Node 2, interface e0b.
In this scenario, what should you do first to solve this problem?

Correct Answer: A
A Twinax cable is a type of copper cable that is used to connect cluster ports to cluster switches1.
A cluster port is a network port that is configured for cluster communication and data access2.
A cluster switch is a network switch that is used to interconnect the nodes in a cluster and provide redundancy and load balancing3.
A cluster network is a network that enables cluster communication and data access between the nodes in a cluster and external clients4.
A cluster network can be degraded due to various reasons, such as misconfiguration, malfunction, or excessive link errors on the cluster ports or the cluster switches.
Link errors are errors that occur on the physical layer of the network, such as CRC errors, length errors, alignment errors, or dropped packets.
Link errors can indicate a problem with the cable, the switch port, the network interface card (NIC), or the cable connector.
In this scenario, the alert messages state that the cluster network has degraded and the errors are being generated from Node 2, interface e0b.
The first step to solve this problem is to replace the Twinax cable between Node 2, interface e0b and the NetApp CN1610 switch, as this could be the source of the link errors.
Replacing the cable could resolve the issue and restore the cluster network to a healthy state.
If replacing the cable does not solve the problem, then other steps may be required, such as checking the switch port, the NIC, or the cable connector, or replacing the switch or the motherboard. Reference:
1: Cluster network cabling, ONTAP 9 Documentation Center
2: Cluster ports, ONTAP 9 Documentation Center
3: Cluster switches, ONTAP 9 Documentation Center
4: Cluster network, ONTAP 9 Documentation Center
[5]: How to troubleshoot CLUSTER NETWORK DEGRADED error messages, NetApp Knowledge Base
[6]: Cluster network degraded due to high CRC errors on cluster ports, NetApp Knowledge Base
insert code

Question 2

You Just used the CLI to create a NetApp ONTAP FlexGroup Volume on a NetApp Cloud Volumes ONTAP instance. After creation, you notice odd behavior in NetApp Cloud Manager.
In this scenario, what Is the reason for this behavior?

Correct Answer: B
= According to the NetApp Knowledge Base1, while Cloud Volumes ONTAP supports FlexGroup volumes, Cloud Manager does not. If you create a FlexGroup volume from System Manager or from the CLI, then you should set Cloud Manager's Capacity Management mode to Manual. Automatic mode might not work properly with FlexGroup volumes. The other options are incorrect because Cloud Volumes ONTAP does support FlexGroup volumes2, the Capacity Management Mode should not be set to Automatic, and Cloud Manager is not required to provision the FlexGroup volume3. Reference = 1, 2, 3
insert code

Question 3

A user mentions that their home drive, that Is an export within a volume, is no longer allowing them to save
files. The drive reports that it Is full, even though It shows that minimal data is written to it.
Which statement would explain this behavior?

Correct Answer: B
insert code

Question 4

When you review performance data for a NetApp ONTAP cluster node, there are back-to-back (B2B) type consistency points (CPs) found occurring on the loot aggregate.
In this scenario, how will performance of the client operations on the data aggregates be affected?

Correct Answer: B
A B2B type consistency point (CP) occurs when a new CP is triggered before the previous CP is completed, due to the second memory buffer reaching a watermark. This can cause write latency to increase as user write operations are not replied until a write buffer frees up. However, this only affects the aggregate that is undergoing the B2B processing, and not the other aggregates on the same node. Therefore, the performance of the client operations on the data aggregates will not be affected by B2B processing on the root aggregate. Reference = What is the Back-to-Back (B2B) Consistency Point Scenario?, What are the different Consistency Point types and how are they measured in ONTAP 9?, What are the different Consistency Point types and how are they measured?
insert code

Question 5

Which two throughput elements are controlled by host applications? (Choose two.)

Correct Answer: C,D
insert code
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • »
[×]

Download PDF File

Enter your email address to download NetworkAppliance.NS0-593.v2024-04-29.q44 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.