FreeQAs
 Request Exam  Contact
  • Home
  • View All Exams
  • New QA's
  • Upload
PRACTICE EXAMS:
  • Oracle
  • Fortinet
  • Juniper
  • Microsoft
  • Cisco
  • Citrix
  • CompTIA
  • VMware
  • SAP
  • EMC
  • PMI
  • HP
  • Salesforce
  • Other
  • Oracle
    Oracle
  • Fortinet
    Fortinet
  • Juniper
    Juniper
  • Microsoft
    Microsoft
  • Cisco
    Cisco
  • Citrix
    Citrix
  • CompTIA
    CompTIA
  • VMware
    VMware
  • SAP
    SAP
  • EMC
    EMC
  • PMI
    PMI
  • HP
    HP
  • Salesforce
    Salesforce
  1. Home
  2. USGBC Certification
  3. LEED-AP-BD-C Exam
  4. USGBC.LEED-AP-BD-C.v2025-12-01.q236 Dumps
  • ««
  • «
  • …
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • …
  • »
  • »»
Download Now

Question 56

Discussing the project goals to help identify the credits and options that the team should attempt is an example of

Correct Answer: C
Discussing the project goals to help identify the credits and options that the team should attempt is an example of developing the LEED Scorecard. The LEED Scorecard is a tool that shows the potential points that a project can achieve under each credit category of the LEED rating system1. Developing the LEED Scorecard involves selecting the most appropriate credits and options based on the project's goals, location, budget, and design2. The scorecard helps the project team track their progress and prioritize their actions throughout the design and construction process1. Reference:
LEED scorecard | U.S. Green Building Council
LEED v4: Building Design + Construction Guide - U.S. Green Building Council
insert code

Question 57

When the LEED AP is applying the Integrative Process to a Building Design and Construction project, when should the Owner's Project Requirements (OPR) be created and updated?

Correct Answer: C
In the Integrative Process, the Owner's Project Requirements (OPR) should be created during the predesign phase and edited throughout the project (C). The OPR documents the owner's goals and objectives, guiding design decisions to align with these priorities. Updating the OPR as necessary ensures that project design and construction remain aligned with the owner's vision and LEED requirements.
insert code

Question 58

For major renovation and new construction projects, the required energy and water-related system analyses should be the same except for

Correct Answer: C
For major renovation and new construction projects, the required energy and water-related system analyses should be the same except for plug and process load needs. Plug and process loads are the electrical loads that are not related to lighting, heating, ventilation, and air conditioning (HVAC) systems, such as computers, appliances, equipment, and machinery. Plug and process load needs may vary depending on the type and function of the building, and they can have a significant impact on the energy performance and demand of the building. Therefore, the project team should analyze the plug and process load needs for each project and design strategies to reduce or optimize them. The other factors, such as site conditions, massing and orientation, and building envelope performance, are common to both major renovation and new construction projects, and they should be analyzed in the same way for both types of projects.
References:
*LEED v4 Reference Guide for Building Design and Construction, Integrative Process Credit: Integrative Process, page 811
*Integrative Process Worksheet2
insert code

Question 59

What is the first step to earn the Water Efficiency Credit, Cooling Tower Water Use?

Correct Answer: D
The first step in earning the Water Efficiency (WE) Credit: Cooling Tower Water Use is to identify the maximum number of cycles of concentration for the cooling tower or evaporative condenser. This step establishes a baseline for water quality and helps determine potential water savings through maximizing the number of cycles, which minimizes water and chemical usage in cooling systems. Subsequent steps may involve chemical analysis (D) or exploring alternative water sources, but setting the cycles is the initial requirement.
insert code

Question 60

Which of the following standards needs to be followed to comply with Indoor Environmental Quality Credit, Thermal Comfort?

Correct Answer: A
To comply with Indoor Environmental Quality Credit, Thermal Comfort, the standard that needs to be followed is ASHRAE 55-2010, Thermal Environmental Conditions for Human Occupancy, with errata or a local equivalent1. This standard specifies the combinations of indoor thermal environmental factors and personal factors that will produce thermal environmental conditions acceptable to a majority of the occupants within the space2. The standard also provides methods for measuring and evaluating thermal comfort, as well as guidance for design, operation, and maintenance of thermal comfort systems2. Reference: Thermal comfort; ASHRAE 55-2010
insert code
  • ««
  • «
  • …
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-BD-C.v2025-12-01.q236 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.