Question 6

The maximum number of points in the Innovation Category that can be achieved by exemplary performance is

Correct Answer: B
The maximum number of points that can be achieved by exemplary performance in the Innovation Category is two points. This is clarified by the LEED documentation, which outlines the combinations of points available for innovation and exemplary performance. Projects can select to achieve a combination of innovation and exemplary performance points, with a maximum of two points for exemplary performance. Therefore, the correct answer is "B: two points."
insert code

Question 7

For Energy and Atmosphere Credit, Advanced Energy Metering, which individual end uses are required to be metered?

Correct Answer: D
insert code

Question 8

The measures called out on the following site plan may contribute to the achievement of which LEED credits?
(Click on Exhibit)
Exhibit

Correct Answer: B
The site plan includes measures for managing rainwater and reducing heat islands. Rain gardens and permeable surfaces are indicated, contributing to the Sustainable Sites Credit for Rainwater Management. The inclusion of parking under the solar canopy contributes to the Heat Island Reduction credit by providing shade and reducing surface temperatures.
References: LEED AP O+M Exam
The site plan provided indicates two distinct sustainability measures: rainwater management and vegetated roof implementation. Rainwater management pertains to strategies that manage and mitigate the impacts of rainfall runoff. It contributes to the Sustainable Sites Credit for Rainwater Management by reducing runoff volume and improving water quality, which is in line with LEED requirements for managing precipitation on-site. Additionally, the presence of a vegetated roof, as shown in the plan, is a strategy for mitigating heat islands. This contributes to the Sustainable Sites Credit for Heat Island Reduction, which aims to minimize the impact on microclimates and human and wildlife habitats by reducing heat-absorbing surfaces.
References:
* The LEED BD+C Reference Guide, specifically the Sustainable Sites (SS) category, outlines the importance of rainwater management and heat island reduction strategies. These are fundamental aspects covered in the LEED AP O+M training materials, which emphasize site sustainability as a critical component of the overall sustainability of a building project.
insert code

Question 9

Instituting a policy to prevent erosion and sedimentation and restore any eroding soils is a requirement of which credit or prerequisite?

Correct Answer: D
The Sustainable Sites Credit, Site Management in LEED AP Operations + Maintenance (LEED AP O+M) V4.1 includes the requirement of instituting a policy to prevent erosion and sedimentation and restore any eroding soils. This is part of the broader strategy to manage the site in a sustainable and environmentally friendly manner.
References: LEED v4: Building Operations + Maintenance Guide, LEED AP with specialty
insert code

Question 10

A LEED AP performs several on-site reviews for LEED compliance and encounters the followingscenarios.
Which scenario requires the installation of additional meters to comply with Energy and Atmosphere Prerequisite, Building-Level Energy Metering?

Correct Answer: D
For a building that shares chilled water usage with other buildings on a campus, if the chilled water consumption is only measured at the campus level, additional meters would be required to comply with the Energy and Atmosphere Prerequisite for Building-Level Energy Metering. Individual metering at the building level is necessary to accurately track and manage the building's specific energy consumption, enabling targeted energy efficiency measures and compliance with LEED requirements.References:The Energy and Atmosphere section of the LEED O+M Reference Guide outlines the requirements for building-level energy metering, including the need for individual metering of significant energy uses such as chilled water in shared systems.
insert code
  • «
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-O-M.v2024-05-08.q83 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.