Question 36

A project is pursuing Materials and Resources Credit, Solid Waste Management - Facility Maintenance and Renovation. The project has generated the following waste as part of their Facility Maintenance and Renovation activities: 2,000 lbs. (907.2 kg) of steel, 900 lbs. (408.2 kg) of carpet, 1,100 lbs. (498.9 kg) of wood, and 1,500 lbs.
(680.4 kg) of wallboard. If the project has diverted 1,800 lbs. (816.4 kg) of steel, 900 lbs. (408.2 kg) of carpet,
1,000 lbs. (453.6 kg) of wood, and 250 lbs. (113.3 kg) of wallboard, what is the actual diversion rate achieved?

Correct Answer: C
insert code

Question 37

Which of the following standards is applicable in order to comply with Indoor Environmental Quality Credit, Thermal Comfort?

Correct Answer: B
ASHRAE 55-2010 is the standard applicable for compliance with the Indoor Environmental Quality Credit, Thermal Comfort. This standard outlines the conditions for acceptable thermal environments and is used for the design, evaluation, and operation of buildings to meet thermal comfort requirements.
References: The LEED v4.1 O+M reference guide specifies that ASHRAE 55-2010 is the standard for thermal comfort, focusing on ensuring quality thermal environments conducive to occupants' comfort and well-being1.
insert code

Question 38

In which of the following ways can a campus project using a Group Approach comply with Water Efficiency Prerequisite, Building-Level Water Metering?

Correct Answer: B
insert code

Question 39

Key functional and operational parameters such as occupied hours of a building, use by space type, required temperature settings, and lighting levels, are specified in the

Correct Answer: C
The Owner Project Requirements (OPR) is a document that details the ideas, concepts, and criteria determined by the owner to be important to the success of the project. It typically includes key functional and operational parameters such as occupied hours of a building, use by space type, required temperature settings, and lighting levels. The OPR is used as a guiding document throughout the design and construction process to ensure that the team is aligned with the owner's vision and goals.
References: LEED v4: Building Operations + Maintenance Guide, Functional / Operational | WBDG - Whole Building Design Guide, Facilities Operations & Maintenance - An Overview - WBDG The Owner Project Requirements (OPR) is a critical document that outlines the functional and operational objectives of a project, reflecting the owner's needs and expectations. This document serves as a foundation for the design team to develop the Basis of Design (BOD) and guides the project through its lifecycle, ensuring that the owner's operational needs, such as occupied hours, use by space type, required temperature settings, and lighting levels, are met. The OPR typically includes information on building occupancy schedules, space usage types, environmental conditions like temperature and lighting requirements, and other owner-driven criteria essential for the building's design and operation. By clearly defining these parameters upfront, the OPR ensures that the project team has a clear understanding of what is expected from the building's performance, facilitating a design that aligns with the owner's vision and operational needs.
References:Based on the LEED AP documents and resources, such as the ASHRAE 90.1-2013 User Manual, which provides guidelines for determining design and operational parameters like lighting wattage for various space types (ASHRAE 90.1-2013, Section 9.1.4) .
insert code

Question 40

When calculating Water Efficiency Credit, Outdoor Water Use Reduction, the irrigation of athletic fields

Correct Answer: C
When calculating the Water Efficiency Credit for Outdoor Water Use Reduction, the irrigation of athletic fields may be included or excluded based on the project's specific circumstances and goals. This flexibility allows projects to tailor their water efficiency strategies to their unique site conditions, uses, and priorities, ensuring that the approach to outdoor water use reduction is both practical and effective.References:The Water Efficiency section of the LEED O+M Reference Guide provides guidance on calculating outdoor water use, offering options for including or excluding certain areas like athletic fields to meet the project's needs.
insert code
  • ««
  • «
  • …
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-O-M.v2024-05-08.q83 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.