Question 101

A design team is working on a new building project and is employing an integrated, whole-building approach. The architects want to increase the size of a glazed opening on the south facing wall. Which team members are first affected by this change?

Correct Answer: D
According to the LEED v4: Building Design and Construction Guide, an integrated, whole-building approach is a process that requires collaboration and communication among all project team members and stakeholders throughout all phases of a project, from pre-design to occupancy and operations. The goal of this approach is to optimize the environmental and human health performance of a building as a whole, rather than focusing on individual components or systems1.
One of the benefits of an integrated, whole-building approach is that it allows the project team to identify and evaluate the interrelationships and trade-offs among various design strategies and decisions, and to optimize the synergies and minimize the conflicts among them1. For example, increasing the size of a glazed opening on the south facing wall may have implications for the daylighting, solar heat gain, thermal comfort, energy use, and mechanical system design of the building2. Therefore, the team members who are first affected by this change are the mechanical engineers, who are responsible for designing the heating, ventilation, and air conditioning (HVAC) system of the building, and ensuring that it meets the thermal comfort and energy performance requirements of the project3. The mechanical engineers may need to adjust the size, type, and location of the HVAC equipment, ductwork, and controls, as well as perform energy modeling and analysis to evaluate the impact of the change on the building's energy consumption and emissions3. The mechanical engineers may also need to coordinate with the architects, lighting designers, and other team members to ensure that the change does not compromise the other design goals and criteria of the project3.
insert code

Question 102

What LEED Building Design and Construction rating system mandates a preliminary LEED meeting with the principal members of the project team to create a LEED action plan that includes the anticipated certification tier, targeted credits and parties responsible for each credit?

Correct Answer: C
Explanation
Data centers is the only LEED BD+C rating system that mandates a preliminary LEED meeting with the principal members of the project team to create a LEED action plan that includes the anticipated certification tier, targeted credits and parties responsible for each credit. This is because data centers have unique design and operational characteristics that require a more integrative and customized approach to achieve LEED certification. The preliminary LEED meeting is intended to facilitate early goal setting, alignment, and communication among the project team members12. References: LEED BD+C Reference Guide, Data Centers, page 91; LEED v4.1 BD+C: Data Centers
insert code

Question 103

Which of the following characteristics are a requirement of a compliant water meter?

Correct Answer: B
A compliant water meter is a device that measures and records the total potable water use of the building and associated grounds. According to the LEED v4 Reference Guide for Building Design and Construction, a compliant water meter must meet the following requirements1:
*It must be permanently installed and measure the total water use of the building and grounds.
*It must have a remote communication capability or be readable from a location that is accessible to building management.
*It must have a data storage capability of at least 18 months, or be connected to a system that can store data for at least 18 months.
*It must have a resolution of 0.5 gallons (2 liters) or less, or the smallest unit of measure that is appropriate for the expected water use of the building.
References:
*LEED v4 Reference Guide for Building Design and Construction, Water Efficiency Prerequisite: Building- Level Water Metering, page 3781
*Water metering | U.S. Green Building Council
insert code

Question 104

What type of project would benefit from showing compliance with Energy and Atmosphere Prerequisite, Minimum Energy Performance, Option 2. Prescriptive Compliance: ASHRAE 50% Advanced Energy Design Guide?

Correct Answer: A
This option allows the project to comply with the minimum energy performance prerequisite by following the prescriptive recommendations of the ASHRAE 50% Advanced Energy Design Guide (AEDG) for the applicable building type and climate zone1. This option simplifies the decision making and analysis process by providing clear and specific guidance on how to achieve 50% energy savings compared to the baseline standard2. This option also reduces the need for energy modeling and documentation, which can save time and money for the project3.
References: = [LEED v4: Building Design + Construction Guide], Minimum Energy Performance Calculator
- ASHRAE 90.1 - 2010, 50 Percent AEDG Free Download - ASHRAE.
insert code

Question 105

Which of the following is an example of a diverse use as defined by Location and Transportation Credit, Surrounding Density and Diverse Uses?

Correct Answer: C
Detailed Explanation:
A public park qualifies as a diverse use under LEED because it is a publicly accessible facility that serves the community. LEED defines diverse uses as those that provide amenities, services, or public resources within walking distance, promoting walkable neighborhoods and reducing reliance on vehicles.
insert code
  • ««
  • «
  • …
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • …
  • »
  • »»
[×]

Download PDF File

Enter your email address to download USGBC.LEED-AP-BD-C.v2025-12-01.q236 Dumps

Email:

FreeQAs

Our website provides the Largest and the most Latest vendors Certification Exam materials around the world.

Using dumps we provide to Pass the Exam, we has the Valid Dumps with passing guranteed just which you need.

  • DMCA
  • About
  • Contact Us
  • Privacy Policy
  • Terms & Conditions
©2026 FreeQAs

www.freeqas.com materials do not contain actual questions and answers from Cisco's certification exams.